Houdini 20.0 Nodes Dynamics nodes

Gas Target Force dynamics node

A microsolver that applies a force towards a target object.

On this page
Since 11.0

The Gas Target Force DOP is a microsolver used in building larger fluid simulations. The Fluid Solver and Smoke Solver DOPs that allow microsolvers to be added before or after the main solver step to extend or tweak the simulation. Alternatively, enterprising people may attempt to build an entire new solver out of microsolvers.

The Gas Target Force DOP builds a force field that directs smoke towards a target shape. It does this by building a Signed Distance field out of the target smoke, using 0.5 as the cut off surface. A force is then applied to the smoke, proportional to the density, in the direction of this target.

When the shape is reached the inward pointing force will be canceled out by hydrostatic pressure.

Parameters

Force

Force Scale

How strongly the force is applied.

Use Existing Goal Field

Instead of building a goal field from the target relationship of this object, an existing scalar field will be used. The name used defaults to goal and is set in the Fields tab.

Animated Goal

If not set, the vector force field of the goal is only built on the first frame. This saves a lot of work if the goal field isn’t animated.

Liquid Mode

When set the Density Field and Goal Field are both treated as signed distance fields. The force is no longer scaled by the density field and no expansion term is applied to the positive error. These changes are appropriate for liquid simulations.

Soft Target

If set no signed distance field is computed. Instead, an error field is built. This error field is used as a goal divergence in computing the desired force vectors. This allows the matching of grey scale fields rather than just the 0.5 cutoff of a fog surface.

Normalize Error

When the Density Field closely matches the Goal Field the error, and hence magnitude of the forces, decreases. Normalizing the error tries to preserve the total force to help the convergence feel constant.

Force Blurring

When in hard-target mode, this is the radius to blur the gradient field with. A blurred gradient avoids harsh discontinuities where smoke is pulled in opposite directions, resulting in a smoother separation when topology changes.

Minimum/Maximum Goal Distance

Controls the range that the goal distance ramp operates on. The minimum goal distance refers to the left side of the ramp, the maximum the right side. Negative values imply inside the goal object.

Map Goal Distance to Force

Scales the force according to how far from the goal object it is. This can be used to disable the suction effect at a far distance, or to cut off the inward force once the smoke reaches the goal.

Guides

Each of the fields that cotnrol the smoke attraction can be visualized in a number of ways. The help for the Scalar Field Visualization or Vector Field Visualization provides more details about how these work.

Fields

These parameters control what name will be used for the input fields and the internal fields.

Density Field

The smoke field to drive to the goal shape. The force is scaled by this field.

Goal Field

The target shape. The 0.5 contour is used as the goal perimeter.

Goal SDF

An SDF version of the target shape built from the 0.5 contour of the goal.

Goal Force Field

A vector field pointing towards the goal field. This is what is used for the force.

Velocity Field

The vector field to add the force to.

Collision Field

The scalar field to use as a collision hint when soft target is enabled. The generated force field will know to avoid the collision objects so specified.

Outputs

First Output

The operation of this output depends on what inputs are connected to this node. If an object stream is input to this node, the output is also an object stream containing the same objects as the input (but with the data from this node attached).

If no object stream is connected to this node, the output is a data output. This data output can be connected to an Apply Data DOP, or connected directly to a data input of another data node, to attach the data from this node to an object or another piece of data.

Locals

channelname

This DOP node defines a local variable for each channel and parameter on the Data Options page, with the same name as the channel. So for example, the node may have channels for Position (positionx, positiony, positionz) and a parameter for an object name (objectname).

Then there will also be local variables with the names positionx, positiony, positionz, and objectname. These variables will evaluate to the previous value for that parameter.

This previous value is always stored as part of the data attached to the object being processed. This is essentially a shortcut for a dopfield expression like:

dopfield($DOPNET, $OBJID, dataName, "Options", 0, channelname)

If the data does not already exist, then a value of zero or an empty string will be returned.

DATACT

This value is the simulation time (see variable ST) at which the current data was created. This value may not be the same as the current simulation time if this node is modifying existing data, rather than creating new data.

DATACF

This value is the simulation frame (see variable SF) at which the current data was created. This value may not be the same as the current simulation frame if this node is modifying existing data, rather than creating new data.

RELNAME

This value will be set only when data is being attached to a relationship (such as when Constraint Anchor DOP is connected to the second, third, of fourth inputs of a Constraint DOP).

In this case, this value is set to the name of the relationship to which the data is being attached.

RELOBJIDS

This value will be set only when data is being attached to a relationship (such as when Constraint Anchor DOP is connected to the second, third, of fourth inputs of a Constraint DOP).

In this case, this value is set to a string that is a space separated list of the object identifiers for all the Affected Objects of the relationship to which the data is being attached.

RELOBJNAMES

This value will be set only when data is being attached to a relationship (such as when Constraint Anchor DOP is connected to the second, third, of fourth inputs of a Constraint DOP).

In this case, this value is set to a string that is a space separated list of the names of all the Affected Objects of the relationship to which the data is being attached.

RELAFFOBJIDS

This value will be set only when data is being attached to a relationship (such as when Constraint Anchor DOP is connected to the second, third, of fourth inputs of a Constraint DOP).

In this case, this value is set to a string that is a space separated list of the object identifiers for all the Affector Objects of the relationship to which the data is being attached.

RELAFFOBJNAMES

This value will be set only when data is being attached to a relationship (such as when Constraint Anchor DOP is connected to the second, third, of fourth inputs of a Constraint DOP).

In this case, this value is set to a string that is a space separated list of the names of all the Affector Objects of the relationship to which the data is being attached.

ST

The simulation time for which the node is being evaluated.

Depending on the settings of the DOP Network Offset Time and Scale Time parameters, this value may not be equal to the current Houdini time represented by the variable T.

ST is guaranteed to have a value of zero at the start of a simulation, so when testing for the first timestep of a simulation, it is best to use a test like $ST == 0, rather than $T == 0 or $FF == 1.

SF

The simulation frame (or more accurately, the simulation time step number) for which the node is being evaluated.

Depending on the settings of the DOP Network parameters, this value may not be equal to the current Houdini frame number represented by the variable F. Instead, it is equal to the simulation time (ST) divided by the simulation timestep size (TIMESTEP).

TIMESTEP

The size of a simulation timestep. This value is useful for scaling values that are expressed in units per second, but are applied on each timestep.

SFPS

The inverse of the TIMESTEP value. It is the number of timesteps per second of simulation time.

SNOBJ

The number of objects in the simulation. For nodes that create objects such as the Empty Object DOP, SNOBJ increases for each object that is evaluated.

A good way to guarantee unique object names is to use an expression like object_$SNOBJ.

NOBJ

The number of objects that are evaluated by the current node during this timestep. This value is often different from SNOBJ, as many nodes do not process all the objects in a simulation.

NOBJ may return 0 if the node does not process each object sequentially (such as the Group DOP).

OBJ

The index of the specific object being processed by the node. This value always runs from zero to NOBJ-1 in a given timestep. It does not identify the current object within the simulation like OBJID or OBJNAME; it only identifies the object’s position in the current order of processing.

This value is useful for generating a random number for each object, or simply splitting the objects into two or more groups to be processed in different ways. This value is -1 if the node does not process objects sequentially (such as the Group DOP).

OBJID

The unique identifier for the object being processed. Every object is assigned an integer value that is unique among all objects in the simulation for all time. Even if an object is deleted, its identifier is never reused. This is very useful in situations where each object needs to be treated differently, for example, to produce a unique random number for each object.

This value is also the best way to look up information on an object using the dopfield expression function.

OBJID is -1 if the node does not process objects sequentially (such as the Group DOP).

ALLOBJIDS

This string contains a space-separated list of the unique object identifiers for every object being processed by the current node.

ALLOBJNAMES

This string contains a space-separated list of the names of every object being processed by the current node.

OBJCT

The simulation time (see variable ST) at which the current object was created.

To check if an object was created on the current timestep, the expression $ST == $OBJCT should always be used.

This value is zero if the node does not process objects sequentially (such as the Group DOP).

OBJCF

The simulation frame (see variable SF) at which the current object was created. It is equivalent to using the dopsttoframe expression on the OBJCT variable.

This value is zero if the node does not process objects sequentially (such as the Group DOP).

OBJNAME

A string value containing the name of the object being processed.

Object names are not guaranteed to be unique within a simulation. However, if you name your objects carefully so that they are unique, the object name can be a much easier way to identify an object than the unique object identifier, OBJID.

The object name can also be used to treat a number of similar objects (with the same name) as a virtual group. If there are 20 objects named “myobject”, specifying strcmp($OBJNAME, "myobject") == 0 in the activation field of a DOP will cause that DOP to operate on only those 20 objects.

This value is the empty string if the node does not process objects sequentially (such as the Group DOP).

DOPNET

A string value containing the full path of the current DOP network. This value is most useful in DOP subnet digital assets where you want to know the path to the DOP network that contains the node.

Note

Most dynamics nodes have local variables with the same names as the node’s parameters. For example, in a Position DOP, you could write the expression:

$tx + 0.1

…to make the object move 0.1 units along the X axis at each timestep.

Dynamics nodes